ILCV3000-G14
An in-line, ball-type check valve.
SYMBOL
When pressure at rises above the spring bias pressure, the ball is lifted and flow
allowed from to .
The valve is closed (checked) from to .
PRESSURE DROP VS.FLOW
OPERATIONDESCRIPTION
Max.Operating Pressure
350bar
Flow
See PRESSURE DROP VS.FLOW graph.
Internal Leakage
2 drops/min max. at 350bar
Cracking Pressure
2.1bar
Temperature
-40
°
F to +250
°
F(-40
°
C to +120
°
C)
Fluids
Mineral-based fluids with viscosities of 7.4 to 420 cSt.
Housing Material
Steel & Ductile iron rated to 350bar
SPECIFICATIONS
Max poppet
Stroke 1.8mm
Torque
If the valve is used as reverse check,
the user needs to change the position of o-ring
32cSt oil @ 40°C
Drilling
In-line Check Valve
D-7
Keta Hydraulics-2023